Delivery from Germany to the world
+49 170 4630876·+49 30 82071039·post@zwodltd.de
Manufacturer catalog

Discontinued Schmersal part numbers

79 numbers discontinued by the manufacturer. We check remaining stock, successor type and equivalent alternatives.

Industrial components from Schmersal

We handle individual part numbers as well as complete BOMs. For hard-to-find or obsolete positions we check additional sources and, where appropriate, alternatives.

Typical workflow
  • Check part number / MPN
  • Compare supply sources
  • Price & lead time
  • Consolidation with other brands
Part numbers

Discontinued Schmersal part numbers (79)

Select a part number to view product details or request price and lead time.

These part numbers have been discontinued by the manufacturer. For each we check remaining stock at distributors in several countries, the official successor type and technically equivalent alternatives. Technical approval of a replacement stays with your engineer. How we handle discontinued parts · All Schmersal part numbers

101019492with Locking sleeve 4 Contacts Mounting depth 91 mm 4 switch position Mounting hole 30.…1010590422 cable entries M 20 x 1.5 Metal enclosure 118 mm x 155 mm x 64 mm ( basic component) A…1010590662 cable entries M 20 x 1.5 Metal enclosure 1 Contact 106 mm x 71 mm x 63 mm (basic comp…101136126Metal enclosure Interlock with protection against incorrect locking. Robust design Long…101152789Adjustable ball latch to 400 N 2 switches in one enclosure Problem-free opening of stre…101158200Level 1: Reset without edge detection, Optional Automatic reset function, Short-circuit…101162240Suitable for the signal processing of outputs with contact sensors 3 safety contacts, S…101163440Monitoring two-hand control panels to EN ISO 13851 2 safety contacts, STOP 0 1 Signalli…101164463Metal enclosure Interlock with protection against incorrect locking. Robust design Long…101164759with maintained and momentary positions hygienic design Protection class IP69K Mounting…101170117Suitable for the signal processing of outputs with contact sensors 2 safety contacts, S…101172210Monitoring of BNS range magnetic safety sensors 3 safety contacts, STOP 0 1 Signalling…101172211Multi-evaluation of up to 6 safety guards Monitoring of BNS range magnetic safety senso…1011739342 safety contacts, STOP 0 6 Signalling outputs Multi-evaluation of up to 6 safety guard…101176197Level 1: Reset without edge detection, Optional Automatic reset function, Level 2: / Op…101176198Level 1: Reset without edge detection, Optional Automatic reset function, Level 2: / Op…101176199Level 1: Reset with edge detection, Level 2: / Opener (NC) Normally open contact (NO) T…101176208Level 1: Reset without edge detection, Optional Automatic reset function, Level 2: / Op…101176209Level 1: Reset without edge detection, Optional Automatic reset function, Level 2: / Op…101176210Level 1: Reset with edge detection, Level 2 Opener (NC) / Opener (NC) Two-functions saf…101176211Level 1: Reset with edge detection, Level 2: / Opener (NC) Opener (NC) Two-functions sa…101176212Level 1: Reset without edge detection, Optional Automatic reset function, Short-circuit…101176213Level 1: Reset without edge detection, Optional Automatic reset function, Short-circuit…101176214Level 1: Reset with edge detection, Short-circuit recognition, Level 2 Opener (NC): Ope…101176215Level 1: Reset with edge detection, Short-circuit recognition, Level 2: Opener (NC) Nor…101176472Suitable for the signal processing of outputs with contact sensors 2 safety contacts, S…101177962Suitable for the signal processing of outputs with contact sensors Suitable for signal…101181616Suitable for the signal processing of outputs with contact sensors Suitable for signal…101182805Input for up to 4 sensors per interface e.g.: magnetic safety switches type BNS, emerge…101182806Input for up to 4 sensors per interface e.g.: magnetic safety switches type BNS, emerge…101182835Suitable for the signal processing of outputs with contact sensors 3 safety contacts, S…101182968Monitoring two-hand control panels to EN ISO 13851 2 safety contacts, STOP 0 1 Signalli…101183408Monitoring two-hand control panels to EN ISO 13851 2 safety contacts, STOP 0101188271Push button with membrane Symbols still clearly visible under transparent membrane101188284Front element mushroom button101188290Front element mushroom button101188297Front element Indicator lights101188311Front element Indicator lights101188320flat dome integrated multi-LED, extra bright in device head101188796Aluminium enlosure without mountings with 3 mounting holes Ø 22.3 mm NOTICE: Available…101188799Emergency Stop button in metal version Ø 38,5 mm 2 black operating buttons (positioning…101188802Emergency Stop button in metal version Ø 49 mm 2 black operating buttons (positioning p…101189095Input for up to 4 sensors per interface e.g.: magnetic safety switches type BNS, emerge…101189096Input for up to 4 sensors per interface e.g.: magnetic safety switches type BNS, emerge…1011905933 safety contacts, STOP 0 1 Signalling output Suitable for the signal processing of out…1011905943 safety contacts, STOP 0 1 Signalling output Suitable for the signal processing of out…1011905953 safety contacts, STOP 0 1 Signalling output Suitable for the signal processing of out…1011905963 safety contacts, STOP 0 1 Signalling output Suitable for the signal processing of out…101190714Suitable for the signal processing of outputs with contact sensors Suitable for signal…101190715Suitable for the signal processing of outputs with contact sensors Suitable for signal…101193562Mushroom button Ex-Zone 1 and 21101195072high calotte integrated multi-LED, extra bright in device head101195366Front element selector switch101195367Front element selector switch101195378Front element key selector switch101195381Front element selector switch101195383Front element key selector switch101195384Front element key selector switch101195504Optional: Short-circuit recognition, Manual reset with edge detection in fail-safe circ…1011955782 safety contacts, STOP 0; 2 safety contacts, STOP 1 Suitable for the signal processing…101195579Level 1: Reset without edge detection, Optional Automatic reset function, Short-circuit…101195591Front element selector switch101204319Metal enclosure Interlock with protection against incorrect locking. Robust design Long…101207737Kit with 4 mounting angles for SLC / SLG 220101207757Kit with 4 mounting angles for SLC / SLG 420 - 425101207758The central fixation is an alternative fixation possibility to the side of the profile.…101207767version for 4-beam light grids101207785Kit with 2 mounting angles for Mirror ULS-A41012083092 safety contacts, STOP 0; 1 safety contact, STOP 1 1 Signalling output Suitable for th…101209242STOP 0 / 1 Function 1 oder 2-channel control Start button / Auto-start Drop-out delay 0…1012103522 safety contacts, STOP 0; 1 safety contact, STOP 1 1 Signalling output Suitable for th…1012124151 Signalling output Suitable for the signal processing of outputs with contact sensors…101212555Suitable for the signal processing of outputs with contact sensors 2 safety contacts, S…103002205Suitable for the signal processing of outputs with contact sensors Suitable for signal…103004340Universal coding with RFID technology Spring pulley connection Series-wiring unlimited…103006151Suitable for the signal processing of outputs with contact sensors Suitable for signal…103015819Repeated individual coding with RFID technology Coding level "High" according to ISO 14…103025178Large wiring compartment Manual release 2 Connector M12, 4- and 8-poles right-hand mode…103027193Door stop with magnetic latching Explosion protection for ATEX Zones 2 and 22 Thermopla…

Not listed? Send us the manufacturer, part number and quantity and we will check additional sourcing options.

CallWhatsAppInquiry
WhatsApp